Our burst chambers and pressure test chambers are designed for destructive testing of materials and components under extreme internal pressure. These systems provide controlled pressurization until rupture, helping you ensure product integrity, compliance, and safety.
Our hydraulic impulse testing systems simulate repetitive pressure cycles, essential for predicting fatigue life in hoses, valves, and fittings. With customizable waveform generation and high-pressure endurance, these impulse test stands are ideal for accelerated durability tests.
For high-risk scenarios, our explosion test chambers are built to contain catastrophic failures safely, making them ideal for stress-testing pressurized components. Additionally, our high pressure accelerated aging test chambers allow you to simulate long-term wear in compressed timeframes—critical for product development and quality validation.
Send us a message
Tell us how we can support you.
+603-6157 3888
+6012-688 4788
(GTS 01-1)
(GTS WI-1)
(GTS-GI-1)
(GTS-GHB-1)
(GTS-HSB-1)
(GTS-TC-1)
(GTS-TS-1)
(GTS IC-1)
(GTS-PH-1)
(GTS-AL-1)
(GTS-V-1)
Component durability, electronics lifes
PCB testing, enclosures, semiconductors
Avionics, materials validation
Packaging integrity, storage simulation
Coating durability, insulation effectiveness
Inquire now for pricing and availability.
(GTS 01-1)
| Model | GTS 01-1 |
|---|---|
| Test Medium | Hydraulic oil, ATF fluid, mineral oil, brake oil, fuel, and more. |
| Application | Power steering tube, brake tube, air-conditioning tube, fuel tube, condenser, evaporator, oil cooler, steel pipe, Bundy pipe, and more. |
| Applicable Standards | QC/T 664, TL 82415, TL 82253, SAE J188, SAE J1681, SAE J191, SAE J1532, SAE J517, GMW 14319, GMW 8150, GMW 15964, GMW 16171, GM 6210, GM 6260, PF 90335, ES 6G91-3A719-AAPAS, ES 3R23-3A212-A |
| Pressure | 0 to 14,500 psi |
| Medium Temperature | −50 to 250 °C (−58 to 482 °F) |
| Testing Chamber Temperature | −50 to 250 °C (−58 to 482 °F) |
| Frequency | 0 to 2 Hz |
| Waveform | Sine, trapezoidal, triangular |
| Simultaneous Test | 2 to 10 pieces |
| Testing Cycles | 0 to 10 million cycles |
(GTS WI-1)
| Model | GTS WI-1 |
|---|---|
| Test Medium | Coolant, water, glycol, brake fluid, etc. |
| Application | Rubber cooling water tube, metal cooling water tube, radiator, ventilation core, heater. |
| Applicable Standards | QC/T 468, TL 52361, GMW 14329, GMW 15904, GMW 14785, GMW 16295, GM 6278, JIS D2602, D321WH-A (HONDA), PF 90080, PF 11118-200, ESDG93-8C012-AA, ESDG93-8260-AA, B22 6142-10-2007-D, DIN 73411-2, DIN 73411 |
| Pressure | 0 to 300 psi |
| Medium Temperature | −50 to 200 °C (−58 to 392 °F) |
| Testing Chamber Temperature | −50 to 200 °C (−58 to 392 °F) |
| Frequency | 0 to 3 Hz |
| Waveform | Sine, trapezoidal, triangular |
| Simultaneous Test | 2 to 10 pieces |
| Testing Cycles | 0 to 10 million cycles |
(GTS-GI-1)
| Model | GTS-GI-1 |
|---|---|
| Test Medium | Compressed air, nitrogen |
| Application | Intercooler, turbo-charging hose, nylon tube, engine manifold tubes, and test pieces using compressed air as the medium. |
| Applicable Standards | QC/T 828, GK1W15803, GL1W16153, GK1W 14 10, EA21, WACA-ESHV1G-6C896-AA1, VOLVO-K413-00 186805 (V4), Geely-NL-3, VOLVO-Ch1A, JLR L550-TPJLR-03-011, SPA-TR CAC 31838680, FORD C2-3 Charge Air Cooler ESJX61-6K77ñ-AA (2014 07 1), NISSAN-L42P-14461 NDS00[1], BMW-G2X-10.5.1_Kuehlmodul G2x_10533102_Alliage |
| Pressure | 0 to 300 psi |
| Medium Temperature | RT + 30 to 300 °C (RT + 86 to 572 °F) |
| Testing Chamber Temperature | −50 to 200 °C (−58 to 392 °F) |
| Frequency | 0 to 2 Hz |
| Waveform | Sine, trapezoidal, triangular |
| Simultaneous Test | 2 to 10 pieces |
| Testing Cycles | 0 to 10 million cycles |
(GTS-GHB-1)
| Model | GTS-GHB-1 |
|---|---|
| Test Medium | Water, water glycol, and hydraulic oil |
| Application | Radiator, condenser, evaporator, intermediate cooler, core and fan heater, oil cooler, heater, pressure meters, fire equipment, metal joints, valves, hose assembly, pipeline, pipe, pressure containers, and pressure transmitter. |
| Pressure | 0 to 72,000 psi |
| Pressure Rise Rate | 50 to 43,000 psi/min |
| Medium Temperature | RT to 180 °C (RT to 356 °F) |
| Ambient Temperature | −60 to 180 °C (−76 to 356 °F) |
| Testing Samples ID | Φ 1/8 to 6 in |
| Length of Test Samples | 4 to 40 in |
(GTS-HSB-1)
| Model | GTS-HSB-1 |
|---|---|
| Test Medium | Hydraulic oil, water, antifreeze, glycol |
| Application | Automobile brake hose, power steering pipe, cooling system pipeline, fuel system pipeline, air-conditioning system pipeline, engineering hydraulic hose, metal pipe, pressure gauge, connector, etc. |
| Pressure | 0 to 58,000 psi |
| Pressure Rise Rate | 50 to 43,000 psi/min |
| Pressure Control Accuracy | ±1% FS |
| Medium Temperature | RT to 180 °C (RT to 356 °F) |
| Ambient Temperature | −60 to 180 °C (−76 to 356 °F) |
(GTS-TC-1)
| Model | GTS-TC-1 |
|---|---|
| Application | Automobile water tank, condenser, evaporator, heater core, oil cooler, water cooler, pipeline. |
| Application Standard | JB/T 10505-2005, JB/T 8577-2005, QC/T 468-2010, GMW 14193, TL 874 Thermal Cycle, TL 82406 VW, S86AB-8005-AA III, ES6G91-8005-AA, ESJX61-8005-AA |
| Temperature Scope of High Temperature Fluid Bath | 50 to 250 °C (122 to 482 °F) |
| Temperature Scope of Low Temperature Fluid Bath | −50 to 50 °C (−58 to 122 °F) |
| Temperature of Ambient Chamber | −40 to 150 °C (±2 °C) (−40 to 302 °F) (optional) |
| Impact Frequency | 1 to 30 times/hour (adjustable) |
| Flowrate of Impact Medium | 5 to 800 L/min |
| Impact Medium | Antifreeze solution, oil, and glycol |
| Simultaneous Test | 1 to 4 pieces |
| Test Pressure | 0 to 70 psi (adjustable) |
| Test Cycles | 1 to 99,999 cycles |
(GTS-TS-1)
| Model | GTS-TS-1 |
|---|---|
| Application | Charge air cooler |
| Application Standard | QC/T 828-2010 |
| Medium Flowrate | 300 to 3,000 kg/h (adjustable) |
| Ambient Temperature | −40 to 150 °C (−40 to 302 °F) (optional) |
| High Temperature Scope of Medium | 90 to 300 °C (194 to 572 °F) |
| Low Temperature Scope of Medium | 10 to 80 °C (50 to 176 °F) |
| Test Medium | Compressed air |
| Impact Frequency | 1 to 30 times/hour (adjustable) |
| Simultaneous Test | 2 to 4 pieces |
(GTS IC-1)
| Model | GTS IC-1 |
|---|---|
| Application | Automobile water tank, heater core (warm air core), water cooling plate, oil cooler, condenser, evaporator heat exchanger, and other products |
| Application Standard | ASTM D2570; QC/T 468-2010; GMW 14167; GMW 15737 |
| Flow Rate of Corrosive Liquid | 1 to 2,000 L/min (adjustable) |
| Temperature of Corrosive Liquid | Room temperature up to 125 °C (257 °F) (adjustable) |
| Pressure | 0 to 70 psi (adjustable) |
| Number of Test Samples | 1 to 4 samples tested simultaneously |
| Volume of Test Samples | < 100 L |
| Mode of Control | Pressure and flow rate controlled simultaneously |
| Corrosion Types | Continuous corrosion, intermittent corrosion, high and low temperature alternating corrosion |
(GTS-PH-1)
| Model | GTS-PH-1 |
|---|---|
| Application | Steel wire weaving hose, spiral wire hose, power steering hose, air-conditioning pipe |
| Test Pressure | 0 to 30,000 psi |
| Test Medium | Water, hydraulic oil |
| Simultaneous Test | 1 to 20 pieces |
| Test Process | Flushing, pressure holding, blow and dry (optional HYDAC cleanliness tester) |
| Hose Connection | Quick connector |
| Mode of Control | Touchscreen or computer control |
(GTS-AL-1)
| Model | GTS-AL-1 |
|---|---|
| Application | Small valves, pipelines, meters, sensors, auto parts, downhole tools, and other pressure components |
| Test Pressure | 0 to 15,000 psi (select any pressure grade as needed) |
| Medium | Compressed air, nitrogen gas |
| Simultaneous Test | 1 piece |
| Leakage Detection Method | Leakage detector, pressure-drop method, air-bubble method, differential-pressure method |
(GTS-V-1)
| Model | GTS-V-1 |
|---|---|
| Application | Automobile pipeline, hydraulic hose, and all kinds of parts under vacuum pressure |
| Application Standard | ISO 6803 and others |
| Vacuum Pressure | 0 to 29.5 inHg (14.5 psi) |
| Pressure Holding Time | 0 to 9,999 min |
| Measuring Accuracy | ≤ ±1% F.S. |
| Inner Diameter of Hose |
1/8 to 2.5 in Length: 8 to 50 in |
| Control Mode | Meter control or computer control |
| Simultaneous Test | 1 piece |