Impulse & Burst Test Chambers

Descriptions

Built for industries that demand the highest levels of safety, durability, and compliance, our burst chambers and pressure chambers are designed to simulate real-world conditions and push components to their breaking point—with accuracy you can trust.

Whether you’re validating the strength of automotive hoses, hydraulic components, or aerospace parts, our burst test chambers and impulse test stands offer unmatched performance and reliability.

Burst Test Chambers

Our burst chambers and pressure test chambers are designed for destructive testing of materials and components under extreme internal pressure. These systems provide controlled pressurization until rupture, helping you ensure product integrity, compliance, and safety.

  • Rated for up to 10,000 bar
  • Compatible with various media: water, oil, air
  • Real-time pressure curve monitoring
  • Fail-safe enclosure design

Impulse Test Stands

Our hydraulic impulse testing systems simulate repetitive pressure cycles, essential for predicting fatigue life in hoses, valves, and fittings. With customizable waveform generation and high-pressure endurance, these impulse test stands are ideal for accelerated durability tests.

  • Complies with ISO, SAE, and other test standards
  • Variable frequency and waveform control
  • Long-cycle fatigue testing made simple

Explosion & High-Pressure Testing

For high-risk scenarios, our explosion test chambers are built to contain catastrophic failures safely, making them ideal for stress-testing pressurized components. Additionally, our high pressure accelerated aging test chambers allow you to simulate long-term wear in compressed timeframes—critical for product development and quality validation.

Get a Quote

Send us a message

Need more help?

Tell us how we can support you.

Customer Services

+603-6157 3888

Free Consultation

+6012-688 4788

Explosion & High-Pressure Testing

Volumetric expansion test
Salt Corrosion test stand
low temperature bending test stand

Applications Across Industries

Automotive

Component durability, electronics lifes

Electronics

PCB testing, enclosures, semiconductors

Aerospace

Avionics, materials validation



Pharma & Medical

Packaging integrity, storage simulation

Construction & Materials

Coating durability, insulation effectiveness

contact us

Ready to explore our chamber solutions?

Inquire now for pricing and availability.

factory (2)
ModelGTS 01-1
Test MediumHydraulic oil, ATF fluid, mineral oil, brake oil, fuel, and more.
ApplicationPower steering tube, brake tube, air-conditioning tube, fuel tube, condenser, evaporator, oil cooler, steel pipe, Bundy pipe, and more.
Applicable StandardsQC/T 664, TL 82415, TL 82253, SAE J188, SAE J1681, SAE J191, SAE J1532, SAE J517, GMW 14319, GMW 8150, GMW 15964,
GMW 16171, GM 6210, GM 6260, PF 90335, ES 6G91-3A719-AAPAS, ES 3R23-3A212-A
Pressure0 to 14,500 psi
Medium Temperature−50 to 250 °C (−58 to 482 °F)
Testing Chamber Temperature−50 to 250 °C (−58 to 482 °F)
Frequency0 to 2 Hz
WaveformSine, trapezoidal, triangular
Simultaneous Test2 to 10 pieces
Testing Cycles0 to 10 million cycles
Model GTS WI-1
Test Medium Coolant, water, glycol, brake fluid, etc.
Application Rubber cooling water tube, metal cooling water tube, radiator, ventilation core, heater.
Applicable Standards QC/T 468, TL 52361, GMW 14329, GMW 15904, GMW 14785, GMW 16295, GM 6278, JIS D2602, D321WH-A (HONDA), PF 90080, PF 11118-200, ESDG93-8C012-AA, ESDG93-8260-AA, B22 6142-10-2007-D, DIN 73411-2, DIN 73411
Pressure 0 to 300 psi
Medium Temperature −50 to 200 °C (−58 to 392 °F)
Testing Chamber Temperature −50 to 200 °C (−58 to 392 °F)
Frequency 0 to 3 Hz
Waveform Sine, trapezoidal, triangular
Simultaneous Test 2 to 10 pieces
Testing Cycles 0 to 10 million cycles
Model GTS-GI-1
Test Medium Compressed air, nitrogen
Application Intercooler, turbo-charging hose, nylon tube, engine manifold tubes, and test pieces using compressed air as the medium.
Applicable Standards QC/T 828, GK1W15803, GL1W16153, GK1W 14 10, EA21, WACA-ESHV1G-6C896-AA1, VOLVO-K413-00 186805 (V4), Geely-NL-3, VOLVO-Ch1A, JLR L550-TPJLR-03-011, SPA-TR CAC 31838680, FORD C2-3 Charge Air Cooler ESJX61-6K77ñ-AA (2014 07 1), NISSAN-L42P-14461 NDS00[1], BMW-G2X-10.5.1_Kuehlmodul G2x_10533102_Alliage
Pressure 0 to 300 psi
Medium Temperature RT + 30 to 300 °C (RT + 86 to 572 °F)
Testing Chamber Temperature −50 to 200 °C (−58 to 392 °F)
Frequency 0 to 2 Hz
Waveform Sine, trapezoidal, triangular
Simultaneous Test 2 to 10 pieces
Testing Cycles 0 to 10 million cycles
Model GTS-GHB-1
Test Medium Water, water glycol, and hydraulic oil
Application Radiator, condenser, evaporator, intermediate cooler, core and fan heater, oil cooler, heater, pressure meters, fire equipment, metal joints, valves, hose assembly, pipeline, pipe, pressure containers, and pressure transmitter.
Pressure 0 to 72,000 psi
Pressure Rise Rate 50 to 43,000 psi/min
Medium Temperature RT to 180 °C (RT to 356 °F)
Ambient Temperature −60 to 180 °C (−76 to 356 °F)
Testing Samples ID Φ 1/8 to 6 in
Length of Test Samples 4 to 40 in
Model GTS-HSB-1
Test Medium Hydraulic oil, water, antifreeze, glycol
Application Automobile brake hose, power steering pipe, cooling system pipeline, fuel system pipeline, air-conditioning system pipeline, engineering hydraulic hose, metal pipe, pressure gauge, connector, etc.
Pressure 0 to 58,000 psi
Pressure Rise Rate 50 to 43,000 psi/min
Pressure Control Accuracy ±1% FS
Medium Temperature RT to 180 °C (RT to 356 °F)
Ambient Temperature −60 to 180 °C (−76 to 356 °F)
ModelGTS-TC-1
ApplicationAutomobile water tank, condenser, evaporator, heater core, oil cooler, water cooler, pipeline.
Application StandardJB/T 10505-2005, JB/T 8577-2005, QC/T 468-2010, GMW 14193, TL 874 Thermal Cycle, TL 82406 VW,
S86AB-8005-AA III, ES6G91-8005-AA, ESJX61-8005-AA
Temperature Scope of High Temperature Fluid Bath50 to 250 °C (122 to 482 °F)
Temperature Scope of Low Temperature Fluid Bath−50 to 50 °C (−58 to 122 °F)
Temperature of Ambient Chamber−40 to 150 °C (±2 °C) (−40 to 302 °F) (optional)
Impact Frequency1 to 30 times/hour (adjustable)
Flowrate of Impact Medium5 to 800 L/min
Impact MediumAntifreeze solution, oil, and glycol
Simultaneous Test1 to 4 pieces
Test Pressure0 to 70 psi (adjustable)
Test Cycles1 to 99,999 cycles
Model GTS-TS-1
Application Charge air cooler
Application Standard QC/T 828-2010
Medium Flowrate 300 to 3,000 kg/h (adjustable)
Ambient Temperature −40 to 150 °C (−40 to 302 °F) (optional)
High Temperature Scope of Medium 90 to 300 °C (194 to 572 °F)
Low Temperature Scope of Medium 10 to 80 °C (50 to 176 °F)
Test Medium Compressed air
Impact Frequency 1 to 30 times/hour (adjustable)
Simultaneous Test 2 to 4 pieces
Model GTS IC-1
Application Automobile water tank, heater core (warm air core), water cooling plate, oil cooler, condenser, evaporator heat exchanger, and other products
Application Standard ASTM D2570; QC/T 468-2010; GMW 14167; GMW 15737
Flow Rate of Corrosive Liquid 1 to 2,000 L/min (adjustable)
Temperature of Corrosive Liquid Room temperature up to 125 °C (257 °F) (adjustable)
Pressure 0 to 70 psi (adjustable)
Number of Test Samples 1 to 4 samples tested simultaneously
Volume of Test Samples < 100 L
Mode of Control Pressure and flow rate controlled simultaneously
Corrosion Types Continuous corrosion, intermittent corrosion, high and low temperature alternating corrosion
Model GTS-PH-1
Application Steel wire weaving hose, spiral wire hose, power steering hose, air-conditioning pipe
Test Pressure 0 to 30,000 psi
Test Medium Water, hydraulic oil
Simultaneous Test 1 to 20 pieces
Test Process Flushing, pressure holding, blow and dry (optional HYDAC cleanliness tester)
Hose Connection Quick connector
Mode of Control Touchscreen or computer control
Model GTS-AL-1
Application Small valves, pipelines, meters, sensors, auto parts, downhole tools, and other pressure components
Test Pressure 0 to 15,000 psi (select any pressure grade as needed)
Medium Compressed air, nitrogen gas
Simultaneous Test 1 piece
Leakage Detection Method Leakage detector, pressure-drop method, air-bubble method, differential-pressure method
Model GTS-V-1
Application Automobile pipeline, hydraulic hose, and all kinds of parts under vacuum pressure
Application Standard ISO 6803 and others
Vacuum Pressure 0 to 29.5 inHg (14.5 psi)
Pressure Holding Time 0 to 9,999 min
Measuring Accuracy ≤ ±1% F.S.
Inner Diameter of Hose 1/8 to 2.5 in
Length: 8 to 50 in
Control Mode Meter control or computer control
Simultaneous Test 1 piece
Seraphinite AcceleratorOptimized by Seraphinite Accelerator